Dimensions |
417 mm x 140 mm x 183 mm (16.4 in. x 5.5 in. x 7.2 in.) |
|
Fittings (on the unit) | Carrier Gas Inlet | 1/4 in. VCR female split nut |
Liquid Inlet | 1/4 in. VCR female | |
Vapor Outlet | 1/2 in. VCR female | |
Compressed Air | 4 mm instant tube fitting | |
Wetted Parts | SS 316, FFKM, PTFE, Nickel | |
Leak Integrity | <1 x 10-9 Pa·m3/s (He) | |
Heater Power Requirements | 220 VAC, 60 Hz, 3600W | |
Carrier Gas | Inert gas recommended | |
Max Carrier Gas Flow1 | 30 standard liters/min N2 at 80 psig 20 standard liters/min N2 at 50 psig |
|
Max. Liquid Flow Rate2 | 6,000 g/hr. (TEOS equivalent) 600 g/hr. (H2O or equivalent) |
|
System Pressure Limit | 150 psig | |
Compressed Air | 90 to 110 psi | |
Temperature Range | 40°C to 200°C | |
Vaporizer Body | Vacuum tight chamber with multi-stage heat exchanger, SS 316 construction | |
Temperature Sensor | 2 Type K thermocouples |
Specifications subject to change without notice
1 Max Carrier Gas Flow Rate is adjustable; visit www.tsi.com/contact to request more information.
2 Max Liquid Flow Rate is process dependent. The spec assumes a vaporizer temperature of 180° C or higher, N2 carrier gas flow ≥20 SLPM, and pressure <10 Torr immediately downstream of the vaporizer.