Range: 0 to ± 30 Std L/min Accuracy: 2% of reading Calibration: CO2 Includes Standard Accessory Kit
Ideal for Insufflator testing
ISO 17025 Accredited Version
The TSI Mass Flow Multi-Meter 5210-7 provides a bi-directional flow rate measurement with 2% of reading accuracy across a wide flow range. Integrated temperature and pressure sensors compensate flow measurements to provide mass flow readings independent of temperature or pressure. In addition to temperature and absolute pressure measurements, a built-in totalizer measurement enables users to make volume measurements as a running total. All 5200 Series inline flow meter models come with a standard accessory kit (see full list below).
5210 mass flow meters include a differential pressure sensor that enables users to measure the pressure differential of flows at the flow meter or at any point in the line. In addition to the totalizer, these volumetric flow meters can make precise volume measurements through the use of flow or pressure triggers. 5210 models also include a built-in data logger that can save synchronized measurement data directly to the flow meter.
Precisely measuring CO2 gas flow, along with measuring low pressure and gas volume, and logging data, make this model ideal for testing CO2 insufflator systems.
View up to four readings simultaneously from the color touchscreen display of this CO2 flow meter. Quickly and easily configure measurements and device settings directly from the flow meter. Connect and operate the gas flow meter through your PC with FLO-Sight software to take advantage of advanced data display and device settings options.
TSI Flow Meters are lightweight, compact, and can measure across a wide dynamic operating range. The 5000 Series Flow Meter also incorporates configurable tube end adapters, touchscreen control, and multiple mounting options. Whether measuring gas flows in a laboratory, manufacturing, or service setting, the 5000 Series Flow Meter can adapt to fit your unique application.
Model 5210-7 low flow flow meter is ideal for insufflator testing and testing capnography systems, because it measures CO2, pressure, and volume.
5000 Series Flow Meters utilize a proprietary platinum film sensor with proven performance that’s been relied upon for more than 35 years. The TSI mass flow sensor design is optimized for applications where high accuracy, fast response, and low pressure drop are performance musts. Fast sensor response ensures accuracy in fluctuating flows and is ideal for closed-loop control systems and integrated volume measurements. The low pressure drop of TSI flow meters minimizes flow circuit back pressure and its impact on the system.
*All 5200 Series flow meters come with 3/8 inch end adapters and end caps attached.*
Looking to calibrate your TSI 5210-7 Flow Meter? TSI now offers worldwide service! To find out about our service, calibration, and repair options, visit our Flow Service page.