Product Details
| Dimensions (HxWxD) |
198 mm x 84 mm x 114 mm (7.8'' x 3.3'' x 4.5'') |
|
| Weight | 2.5 kg (5.6 lb) | |
| Fittings (on the unit) | Carrier Gas Inlet | 1/4 in. VCR female split nut |
| Liquid Inlet | 1/8 in. VCR female | |
| Vapor Outlet | 1/4 in. VCR female split nut | |
| Compressed Air | 4 mm instant tube fitting | |
| Wetted Parts | SS 316, PEEK, Elgiloy®, Nickel | |
| Leak Integrity | ≤ 1x 10-8 Pa·m3/s Helium | |
| Heater Power Requirements1 | 208 VAC, 60 Hz, 450 W | |
| Carrier Gas | Inert gas recommended | |
| Max Carrier Gas Flow1 | 2.0 standard liters/min N2 @ 50 psig | |
| Max Liquid Flow2 | 7 g/min (TEOS or equivalent) | |
| System Pressure Limit | 150 psig | |
| Compressed Air | 90 to 110 psig | |
| Temperature Range3 | 40°C to 180°C | |
| Temperature Sensor | 2 type Ƙ thermocouples | |
| Accessories | Power cable included (3 m). AMP CPC, 4 pin connector with 3 flying leads on opposite end | |
Specifications subject to change without notice.
1 Max Carrier Flow, Heater Power (W) and Line Voltage are factory adjustable, visit www.tsi.com/contact to request more information.
2 Max. liquid flow is process dependent. The spec assumes a vaporizer temperature of 180°C, max. carrier gas flow and pressure <50 Torr immediately downstream of the vaporizer.
3 Appropriate venting is required.