Hydronic Manometers

Hydronic manometers help technicians balance hot and chilled water systems that feed air handlers, terminal units, and critical cooling loads. Accurate differential pressure readings across coils and valves support flow calculations, pump optimization, and comfort control in dispatch centers, detention facilities, and labs. Portable instruments with temperature compensation, hose sets, and quick-connects help teams diagnose low flow, verify setpoints, and document performance after service or incident recovery. The result is stable HVAC operation that supports agency readiness and occupant comfort.

Products

Hydronic Manometer HM675

Hydronic Manometer Model HM675 is used to balance hydronic heating and cooling systems, check...

View Product

Hydronic Manometer HM685

Hydronic Manometer HM685 is used to balance hydronic heating and cooling systems, check pump...

View Product

Water-side performance directly affects air-side results. Hydronic manometers give facilities teams the differential pressure data needed to calculate flow, validate valve authority, and tune pumps and coils — key steps for reliable ventilation and comfort across public safety buildings.

Where They Help

  • Dispatch and Command: Maintain stable cooling/heating for equipment rooms and occupied spaces.
  • Detention and Housing: Support temperature stability in zones with variable occupancy.
  • Labs and Training Centers: Verify coil performance for ventilation demands and comfort.
  • Post-Event Recovery: Confirm restored water-side performance after outages or repairs.

Capabilities

  • Differential Pressure Measurement: Quantify pressure across coils, strainers, and control valves.
  • Flow Determination: Use valve charts or Cv/Kv values with measured ΔP to estimate flow.
  • Temperature Considerations: Account for fluid temperature and glycol percentage where applicable.
  • Data Logging: Record readings with time stamps to support maintenance and commissioning reports.

Field Tips

  • Bleed Air: Purge air from hoses and ports for stable readings.
  • Proper Connections: Use appropriate adapters to avoid leaks at test ports.
  • Baseline and Trend: Capture pre- and post-adjustment values for validation.
  • Pair With Air-Side Tools: Combine hydronic results with airflow and temperature data to close the loop.

Selection Guidance

  • Pressure Range and Resolution: Choose instruments suited to expected ΔP across your components.
  • Fluid Compatibility: Confirm hose and seal materials for water/glycol mixes.
  • Accessories: Include hoses, probes, and quick-connects for common valve types.
  • Durability: Field-ready housings and protective cases support frequent deployment.

A disciplined approach to hydronic measurement helps agencies reduce hot/cold calls, support energy goals, and improve occupant experience. By aligning water-side balancing with air-side verification, teams create a stable foundation for reliable HVAC performance across diverse public saf


   close carousel