Videos and Quick Tips
AeroTrak+ Portable Particle Counters A100 Series
The AeroTrak™+ Portable Particle Counter A100 Series, for use in monitoring or classifying cleanroom manufacturing environments, requires no manuals to operate, significantly reducing the chance for user error. Just press START and you’re ready for measurement.
Experience the benefit in use by watching the videos included in this series. You’ll see how this instrument has been engineered for you to make your job easy.
How to Use the Portable Particle Counter
- Just Press Start to Begin Manually Counting Particles in Your Cleanroom
- How To Do Quick, Easy Cleanroom Classification
- How To Easily and Quickly Monitor Cleanrooms
- Annex 1 Ready Cleanroom Classification Testing
- How to Easily Track Samples During Cleanroom Certification or Monitoring
- Cleanroom Compliance is Easy with the Capability to Run Quick Reports
- Cleanroom Classification Zone Creation for ISO 14644, GMP EU Annex 1 or China GMP Compliance
- Quickly Setup a Zone for Efficient Cleanroom Monitoring
- Advantages of Creating a Workflow When Monitoring a Cleanroom
How to Use the Portable Particle Counter with TrakPro™ Lite Secure (TPLS) Software
Just Press Start to Begin Manually Counting Particles in Your Cleanroom
Start taking particle counts in your cleanroom right away with the TSI AeroTrak™+ A100 Portable Particle Counter from TSI. Just press Start and you’re ready for measurement. Easy settings enable you to quickly take control of your particle counter for easy cleanroom monitoring.
How To Do Quick, Easy Cleanroom Classification
Classification is an important part of a cleanroom certification or qualification. Whether testing to comply with ISO 14644-1, EU GMP Annex 1, or China GMP, the TSI AeroTrak™+ A100 Portable Particle Counter makes this easy. Just press Start and classification testing begins.
How To Easily and Quickly Monitor Cleanrooms
Easily and quickly monitor cleanrooms using the TSI AeroTrak™+ Portable Particle Counter A100 Series. Just press Start and you're ready for measurement. Easy settings let you take control of your particle counter to make your job easier. Set your limits and ensure compliance with automated alarms and reporting.
Annex 1 Ready Cleanroom Classification Testing
The classification requirements in EU GMP Annex 1: Manufacture of Sterile Products have changed. Some limits have changed while others are no longer specified. The TSI AeroTrak™+ Portable Particle Counter A100 Series has been engineered to support these changes. This includes updated limits and the ability to define the limits that are no longer specified to assure that your classification testing complies with the new EU GMP Annex 1.
How to Easily Track Samples During Cleanroom Certification or Monitoring
Sample tracking with the TSI AeroTrak™+ A100 Portable Particle Counter is easy during certification or monitoring of your cleanroom. By simply selecting a sample location, the sample tracker feature displays color-coded progression while sampling so that you can easily view and be real-time alerted to the sampling in process.
Green = sampling successfully completed with no alarms
Yellow = sampling alert limit was crossed
Red = sampling action limit crossed
Blue = sample actively being collected
Gray = not yet sampled
Cleanroom Compliance is Easy with the Capability to Run Quick Reports
It’s easy to create a report with the AeroTrak™+ A100 Portable Particle Monitor. After you’ve collected the data from all locations in a zone, use the onboard reporting software to make a report. Simply apply your desired filter, for example by zone name, and click the icon to generate your desired report. Report format options include PDF or secure XML that can be downloaded for easy compliance.
Cleanroom Classification Zone Creation for ISO 14644, GMP EU Annex 1 or China GMP Compliance
Setting up a zone for formal classification has never been easier using the AeroTrak™+ A100 Portable Particle Counter. With preloaded templates for ISO 14644, GMP EU Annex 1 and China GMP, just input the sampling size of your area and let the particle counter do the work. It will automatically calculate the number of sample locations, needing you to simply select the classification to certify to.
Quickly Setup a Zone for Efficient Cleanroom Monitoring
Setting up a zone for monitoring has never been easier using the AeroTrak™+ A100 Portable Particle Counter. With the click of a button, select and name the zone and set sample parameters by quickly entering the sample time volume and cycle frequency as well as alarm limits. Watch this example to see how quick and easy it is to start collecting data, specific to your standard operating procedure (SOP).
Advantages of Creating a Workflow When Monitoring a Cleanroom
It’s easy to create a scheduled workflow using the AeroTrak™+ Portable Particle Counter. This feature acts as a filter that locks out selected sample zones and locations to ensure you never sample the wrong location or miss a sample when monitoring a cleanroom. This safeguards that you are not deviating from your standard operating procedure (SOP).
Connecting Components - Model A100 to TPLS
Learn how to connect your AeroTrak™+ A100 Portable Particle Counter to the TrakPro™ Lite Secure (TPLS) Software for easy instrument configuration, data review, and report generation. This video walks you through the connection process using USB, wired Ethernet, or Wi-Fi.
Easily Manage Users and Settings - Model A100 to TPLS
Learn how to connect your AeroTrak™+ A100 Portable Particle Counter to the TrakPro™ Lite Secure (TPLS) Software for easy instrument configuration, data review, and report generation. This video walks you through the connection process using USB, wired Ethernet, or Wi-Fi.
Efficiently View Data - Model A100 to TPLS
Learn how to connect your AeroTrak™+ A100 Portable Particle Counter to the TrakPro™ Lite Secure (TPLS) Software for easy instrument configuration, data review, and report generation. This video walks you through the connection process using USB, wired Ethernet, or Wi-Fi.