Auto-Load 10 nm Particle Deposition System 2300G3A - 10 nm
This fully automated particle deposition system deposits PSL and SiO2 spheres as small as 10 nm. Calibrate and qualify your defect inspection tools with ease, confidence, and efficiency by producing high volumes of high-quality custom 300 mm and 200 mm contamination standards....
Qualitative Fit Testing with FitPro™ Ultra Fit Test Software
Available in US only. Software application with step-by-step guidance on conducting a qualitative fit test (QLFT) consistently and correctly.Sold in Package Pricing. Software Only (Laptop not included).
Low-Flow Turbo II Vaporizers 2852PE and 2852PE-P
MSP's Turbo II™ Vaporizer 2852PE is designed for high-precision microelectronic applications that require low to mid vapor flow rates. Based off of the field proven, highly reliable, and low maintenance MSP Turbo™ Vaporizers, the new 2852PE provides stable vapor concentrations...
Low-Flow Turbo II Vaporizer 2852NP
MSP's Turbo II™ Vaporizer 2852NP is designed for applications that require low to mid vapor flow rates. Based off of the field proven, highly reliable, and low-maintenance MSP Turbo™ Vaporizers, the new 2852NP provides stable vapor concentrations while maintaining a very small...
Oxygen Gas Mass Flow Meter plus Kit 5200-6
Range: 0 to ± 30 Std L/min
Accuracy: 2% of reading
Calibration: O2
Includes Standard Accessory KitISO 17025 Accredited Version
Air / Oxygen Gas Mass Flow Meter (plus Kit) 5210-2
Range: 0 to ± 30 Std L/min
Accuracy: 2% of reading
Calibration: Air, O2, N2*
Includes Standard Accessory KitIdeal for Pulse Dose Oxygen Concentrator testing*Nitrogen gas is a correction from the air calibrationISO 17025 Accredited Version
Air / Oxygen Gas Mass Flow Meter (plus Kit) 5320-2
Range: 0 to ± 300 Std L/min
Accuracy: 2% of reading
Calibration: Air, O2, N2*
Includes Standard Accessory KitIdeal for CPAP testing for R&D applications*Nitrogen gas is a correction from the air calibrationISO 17025 Accredited Version
Dev-Dep Development Reticle Contamination Standards
Reticle/photomask contamination standards consist of particles deposited on 6 inch reticles with the industry's best particle size and count control. These certified standards for reticle inspection tools are totally customized for each customer.
Air / Oxygen Gas Mass Flow Meter (plus Kit) 5220-2-AC
Flowmeter +DP +RH, 30 lpm, Air, O2, N2, 3/8, 1/4 in, 10mmISO 17025 AccreditedRange: 0 to ± 30 Std L/min
Accuracy: 2% of reading
Calibration: Air, O2, N2*
Includes Standard Accessory Kit*Nitrogen gas is a correction from the air calibration
Certifier™ Plus Test System Standard Kit 4080-S-AC
ISO 17025 AccreditedA handheld, full-featured system capable of testing virtually all models of ventilators: adult, pediatric, anesthesia, neonatal and high-frequency. It can also test a variety of other medical equipment such as anesthesia gas delivery machines, air oxygen...